Brand Name :BFEC
Model Number :DMF-T-62S
Certification :CE
Place of Origin :China
MOQ :1 piece
Price :Negotiation
Payment Terms :T/T , Western Union
Supply Ability :1000 pcs
Delivery Time :within 1-30 working days after payment
Packaging Details :Plastic bags,Boxes, Cartons, Pallets,or according to customer's requirement
Material :Aluminium
Working Temperature :-20 to 100 C
Working pressure :7.5 bar
Diaphragm :NBR
Structure :Diaphragm
Media :Gas
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

2/2 Way Pulse Jet Valve Through Electromagnetic Pulse Valve DMF-T-62S 2.5Inch DN62

Features

1.Model: DMF-T-62S

2.Port size:2-1/2"

3.Specially designed for reverse jet-type dust collector systems

4.High flow Cv(s) to 140 for effective bag cleaning

5.High cycle life

6.Fast opening/closing

Specification

DMF-T-62S
Center hole distance Φ220
Kv/Cv 117.67/130.32
Blowing area(m²) 27~38
Air inlet/Outlet size G2-1/2" G2-1/2"
Weight(kg) 4.1

Fluids Filtered
Diaphragm NBR: -20~120 ℃
fluororubber: -30~180 ℃
Nitrile: -40~120 ℃
Pressure range From 0.5 to 7.5 bar
Cover Die-cast aluminium
Body Die-cast aluminium
Pilot Base Brass (Chromed)
Pilot Stainless Steel
Diaphragm NBR
Bolts and screws Stainless Steel
Diaphragm Backing disk Stainless Steel
Diaphragm spring Stainless Steel

Drawings

2/2 Way Pulse Jet Valves , Through Electromagnetic Pulse Valve DMF-T-62S 2.5Inch DN62

Details Show

2/2 Way Pulse Jet Valves , Through Electromagnetic Pulse Valve DMF-T-62S 2.5Inch DN622/2 Way Pulse Jet Valves , Through Electromagnetic Pulse Valve DMF-T-62S 2.5Inch DN62

Delivery
1. If the products we have in store, we will send it out ASAP after payment.
2. If the products which were customized, we will complete the production within a specified period of time, and send it out the first time, we can promise it.
3. Also we can send by your delivery acount if you want.
4. We have a variety of ways to send goods, usually DHL, Fedex, TNL will be normal ways. If you require use of a courier, we can do it.

Competitive Advantage

Our product features Our Services Guarantee:
1) Competitive price 1) Prompt respond (Reply with 24 hours)
2) Good quality 2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging 3) Registration support.
4) Produce according to Customers’ instruction 4) Photos/videos are available during production.
5) None delay shipment 5) Loading inspection, and send loading photos before shipment.

The installment introduction:
1. First, Confirm the pulse valve in good condition and then installed
2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.

After-sale Service
We can provide a series of after-sale service, such as product introduction, mounting, debugging, technical support and so on.


The exhaust chamber volume of improved DMF pulse valve is increased. The permeability magnetic material of pulse valve is increased, and also, the materials of structure of diaphragm and pressure spring are improved, so that the exhaust volume of valve is increased to raise the magnetic strength and sensitivity as well as the element reliability and operation stability of pulse valve. Its service life will be greatly prolonged.

Inquiry Cart 0