Add to Cart
1. Product Name: CA20DD FLY/AIRWOLF Diaphragm Valves DD Series dust collector pulse valves 3/4" Aluminium Alloy Pulse Solenoid Valve
2. Order code
Ordering Code | Port Size | Orifice | Flow Value | Weight (kg) | ||
G Threaded | mm | Kv | Cv | CA | RCA | |
CA20DD | 3/4" | 20 | 12 | 14 | 1.25 | |
CA45DD/RCA45DD | 1 1/2" | 40 | 44 | 51 | 2.30 | 2.15 |
3. Installation
For your safety do not pressurise system until all valves and pipes are fully secured. Do not attempt to remove a fitted valve while system is under pressure. 1. Prepare supply and blowtube pipes* to suit valve specification. Avoid installing valves underneath the tank. 2. Ensure tank and pipes are free from dirt, rust or other particulate. 3. Ensure supply air is clean and dry. 4. Mount valve to inlet pipes and blowtube to valve, tighten dresser nut. 5. Tanks and pipes must be independently restrained from valve. 6. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only). 7. Apply moderate pressure to system and check for installation leaks. 8. Fully pressurise system. 9. Test fire and listen for proper actuation and crisp pulse noise.
4. Description
High performance diaphragm valve with dresser nut ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
5. Construction
Construction | |
Body | Aluminum (Diecast) |
Washer | SS 304 |
Armature | SS 430FR |
Core and Plugnut | Stainless steel |
Core Spring | SS 304 |
Sealing & disc | NBR(nitrile/buna-n) |
Screws | SS302 |
Diaphragm | PA-6(Standard), fluororubber |
Shading coil | Copper |
Connector | DIN43650A |
Voltage | DC: 24V, AC: 24V, 48V, 110V, 230V |
Working Temperature | -20 to +85℃ Nitrile seals -29 to +232℃ fluororubber seals |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Recommended on time range | 50-500ms |
Recommended time between pulses | 1 minute or Less |
6. Operation
Recommended on time range: 50-500ms
Recommended time between pulses: 1 minute or greater
7. Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning and its variations including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
8. Maintenance
Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually.
9. Approvals
Integrally piloted valves meet the requirements of:
• Atex II 2D Mechanical
• CSA (C&US), C22.2 No. 139-1982 UL Std No. 429
• C-Tick - integral pilots
• EMC (89/336/CE) - integral pilots
10. Drawing
11. Product show
12. Serves time
0:00 - 23:59