1.ISO9001:2000, CE marked,
2.Ordering Code: 139 100 , 139 101, 139 103, 125 653, 125 654, 125 656, 125 657, 125 658, 125 660, 126 284, 126 285,
126 287, 139 104, 139 105, 139 107, 126 264, 126 265, 126 267, 126 276, 126 277, 126 279, 126 292, 126 293,
126 295
3.port size: 1/8" 1/4" 3/8", 1/2"
4.Medium: Air, Water, light Oil
5.Design:
2-way solenoid valve, direct acting, normally closed (Circuit
function A).
6.Temperature:
Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature 104 °F (40 °C)
Max. Fluid Temperature 194 °F (90 °C)
The UL-listed valve for Hazardous Locations is suitable for the
fluids air, inert gas, water and gasoline.
For Hazardous Locations Div. 1 (T6 rated)
Max. Ambient Temperature 104 °F (40 °C)
Max. Fluid Temperature 140 °F (60 °C)
For Intrinsically Safe Apparatus for use in Class I, II and III,
Division 1 Hazardous Locations (T6 rated)
Max. Ambient Temperature 140 °F (60 °C)
Max. Fluid Temperature
7.Pressure Range:
Maximum inlet pressure:1.05Mpa
8.Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal shavings, pipe sealing materials, welding scale
etc.). Installation as required but preferable with coil uppermost.
Installation in this position tends to prevent foreign matter
remaining in core tube (increased life). Do not put any loads on
coil unit.
PTFE tape is recommended for sealing ports. Mounting is
accomplished by means of four M4 x 8 mm tapped holes
located on the valve underside. Letters on valve body indicate
pressure port, exhaust and outlet of the valve.
9.Electrical Connection:
Ensure supply voltage/frequency corresponds with that on label.
Voltage tolerance is ± 10 %.